What size heat pump do I need?

Short answer

A 1,500 square foot home with average insulation needs about 4 tons (45,000 BTU) in a moderate climate, 3.5 tons in a mild one and 4.5 tons in a cold one. One ton is 12,000 BTU per hour.

Work it out for your numbers

Heat pump size

4 tons

Capacity needed
45,000 BTU per hour
Exact tons
3.75 tons

Heat pump size by home size and climate

Home sizeMild (zones 1–3)Moderate (zone 4)Cold (zones 5–7)
1,000 sq ft2.5 tons2.5 tons3 tons
1,500 sq ft3.5 tons4 tons4.5 tons
2,000 sq ft4.5 tons5 tons6 tons*
2,500 sq ft5.5 tons*6.5 tons*7.5 tons*

Average insulation, rounded up to the next half ton. *Residential heat pumps top out at 5 tons, so larger loads usually mean two systems or a zoned setup.

How the estimate works

Floor area times about 25 BTU per square foot in mild climates, 30 in moderate and 35 in cold ones, where the heat pump has to keep up with winter heating rather than just summer cooling. Then divide by 12,000 for tons and round up to the half-ton steps heat pumps are sold in.

Cold climates

Standard heat pumps lose capacity as it gets colder. If your winters drop well below freezing, look for a cold-climate model rated to keep most of its capacity at 5°F, or plan on backup heat such as electric strips or your existing furnace.

Sizing matters more than with a furnace

An oversized heat pump runs in short cycles, which in summer means it cools the air without running long enough to pull out humidity. Ask for a Manual J load calculation before you sign, and compare it with these numbers.

Single rooms and mini-splits

Ductless mini-splits are sized per room or zone. For one room, the AC BTU calculator or heater size calculator is a better fit.

What the efficiency ratings mean

Heat pumps sold in the US carry two ratings. SEER2 measures cooling efficiency over a season and HSPF2 measures heating efficiency. Higher is better for both. In a cold climate, HSPF2 and the unit’s capacity at low temperatures matter more than SEER2; in a hot climate, it’s the other way around.

Backup heat

Most ducted heat pumps include electric resistance strips in the air handler for the coldest days and for defrost cycles. They work, but they’re expensive to run, so a correctly sized heat pump uses them as little as possible.

A dual-fuel system pairs the heat pump with a gas furnace instead. The heat pump handles most of the winter and the furnace takes over when it gets very cold. It’s a common choice when a home already has gas.

Ducted or ductless

If your home has ducts in good condition, a ducted heat pump replaces a furnace or central air conditioner directly. Without ducts, or for additions and rooms the ducts don’t reach, ductless mini-splits put a small indoor unit in each room or zone, connected to an outdoor unit by a small line set. Each indoor head needs to be sized for its own room, not just the house total.

Questions to ask a contractor

  • Did you do a Manual J load calculation, and can I see it?
  • What is this unit’s heating capacity at 5°F, and does it cover my home’s heat loss on the coldest days?
  • Are my ducts big enough for this system’s airflow, and are they sealed?
  • What backup heat is included, and at what outdoor temperature will it come on?
  • Does this system qualify for any utility rebates or tax credits?

Common questions

How many square feet does a 3 ton heat pump cover?

Roughly 1,200 square feet in a moderate climate and up to about 1,450 in a mild one, with average insulation.

How many BTU is a ton?

12,000 BTU per hour. A 3-ton heat pump is 36,000 BTU.

Can a heat pump heat my house in winter?

Yes, in most US climates. In very cold areas, choose a cold-climate model or keep backup heat for the coldest days.

Updated November 16, 2026. Figures are estimates for planning. Check product labels and local codes before you buy or build.