Air conditioner BTU calculator
Enter the room size and a few details about it. You’ll get the BTU rating to shop for and the nearest standard unit size.
Cooling capacity
6,000 BTU/hr
- Look for a unit of
- 6,000 BTU (0.5 tons)
- Room size
- 180 sq ft
- Chart starting point
- 6,000 BTU/hr
Shop for this project
As an Amazon Associate, Measure the Dream earns from qualifying purchases.
How it works
The starting point is the room air conditioner sizing chart published by Energy Star, which matches square footage ranges to a BTU rating. The calculator then applies Energy Star’s adjustments: 10% less for a heavily shaded room, 10% more for a very sunny one, 600 BTU for each regular occupant beyond two, and 4,000 BTU if the room is a kitchen.
It then rounds up to the next common unit size you’ll actually find on a store shelf.
Example
With room length 15 ft, room width 12 ft, sun exposure: average, people who regularly use the room 2, is it a kitchen: no, the answer is 6,000 BTU/hr.
How to measure
Measure the room’s length and width. If the room opens into another space without a door, such as a living room that runs into a dining area, measure the whole open area, since the air conditioner has to cool all of it.
Then think about the conditions: rooms that get strong afternoon sun need about 10% more capacity, shaded rooms about 10% less, and a kitchen adds about 4,000 BTU for cooking heat.
Air conditioner size by room size
From the Energy Star sizing chart, for two people and no kitchen. Values are cooling capacity in BTU per hour.
| Room size | Heavily shaded | Average | Very sunny |
|---|---|---|---|
| 10 × 10 ft | 4,500 | 5,000 | 5,500 |
| 12 × 12 ft | 4,500 | 5,000 | 5,500 |
| 12 × 15 ft | 5,400 | 6,000 | 6,600 |
| 15 × 20 ft | 6,300 | 7,000 | 7,700 |
| 20 × 20 ft | 8,100 | 9,000 | 9,900 |
| 20 × 25 ft | 10,800 | 12,000 | 13,200 |
Common mistakes
- Buying the biggest unit. An oversized air conditioner cools the room quickly and shuts off before it removes humidity, leaving the room cold and clammy.
- Comparing portable and window units by the big number. Portable units list a lower “SACC” rating that reflects real-world cooling, so compare those figures, not the ASHRAE number.
- Ignoring the plug. Large window units, often 15,000 BTU and up, may need a 230 volt outlet. Check before you buy.
- Forgetting about extra people. Add about 600 BTU for each person beyond two who regularly uses the room.
Tips before you buy
- Bigger isn’t better. An oversized unit cools the room fast and shuts off before it removes much humidity, leaving the room cold and clammy.
- Ceilings over 8 feet, poor insulation or a hot, humid climate can push you up a size. Lots of shade and good insulation can pull you down.
- For a whole house or central system, get a professional load calculation (Manual J) rather than using a room chart.
- One “ton” of cooling is 12,000 BTU per hour.
Common questions
What size air conditioner do I need for a 500 sq ft room?
12,000 BTU per Energy Star’s chart, before adjustments for sun, people or a kitchen.
What size AC for a 12×12 bedroom?
144 square feet calls for 5,000 BTU on the chart. A very sunny room or more than two occupants may need the next size up.
How many BTU is a ton of air conditioning?
12,000 BTU per hour. A 24,000 BTU unit is a 2-ton unit.