Attic insulation calculator

Measure the insulation you already have and choose a target R-value. The calculator tells you how much more to add.

R-49 to R-60 suits most of the US. R-30 to R-49 for the warmest areas.

Add

11.1 inches of insulation

Current R-value
R-10 (estimated)
R-value to add
R-39
Volume to add
1,114 cubic feet
Attic floor area
1,200 sq ft

Shop for this project

As an Amazon Associate, Measure the Dream earns from qualifying purchases.

How it works

R-value measures resistance to heat flow, and each type of insulation provides roughly a fixed R-value per inch. The calculator estimates your current R-value (depth × the R-per-inch of what you have), subtracts it from your target, and divides by the R-per-inch of what you’re adding.

For blown-in insulation, the bag’s coverage chart tells you how many bags give that depth over your attic area. Use it for the bag count, since densities vary by product.

Example

With attic length 40 ft, attic width 30 ft, target R-value: r-49, existing insulation depth 4 in, existing insulation type: loose-fill fiberglass (about R-2.5/in), insulation you’re adding: loose-fill cellulose (about R-3.5/in), the answer is 11.1 inches of insulation.

How to measure

Measure the attic floor area, which is usually close to the footprint of the house below it. Then measure how deep the existing insulation is in several places with a ruler between the joists; it’s often uneven, especially near the eaves.

Identify what’s there: fluffy pink or yellow loose fill or batts are fiberglass, gray shredded paper is cellulose, and dense gray-green or brown batts are often mineral wool. The type sets how much R-value each inch provides.

Inches of cellulose to add

Loose-fill cellulose at about R-3.5 per inch, on top of existing loose-fill fiberglass.

Existing insulationTo R-38To R-49To R-60
None10.91417.1
3 in8.711.915
6 in6.69.712.9
9 in4.47.610.7

Common mistakes

  • Blocking the soffit vents. Install baffles at the eaves so air can still flow from the soffits to the roof vents.
  • Burying recessed lights that aren’t rated for it. Only IC-rated fixtures can be covered; check before blowing insulation over them.
  • Skipping air sealing. Seal gaps around pipes, wires, chimneys and the attic hatch first; insulation doesn’t stop air leaks.
  • Stepping between the joists. The ceiling below won’t hold you. Lay boards across the joists to kneel on.

Tips before you buy

  • ENERGY STAR publishes recommended attic R-values by climate zone. Most of the US falls in the R-49 to R-60 range.
  • Seal air leaks around light fixtures, pipes and the attic hatch before adding insulation. Leaks undo a lot of insulation.
  • Keep insulation clear of soffit vents with baffles, and away from recessed lights not rated for contact.
  • Old, compressed insulation performs below its nominal R-value, so the estimate here may be optimistic.

Common questions

How many inches of blown-in insulation for R-49?

About 14 inches of cellulose, or roughly 20 inches of loose-fill fiberglass.

How much attic insulation do I need?

Most US homes should aim for R-49 to R-60 in the attic, or R-30 to R-49 in the warmest areas.

Can I put new insulation over old insulation?

Usually yes, if the old insulation is dry and not moldy. Unfaced insulation over the top avoids trapping moisture.

Add this calculator to your website

Free for any site or blog. Paste this code where you want the calculator to appear. The short script makes it resize to fit; if your site doesn’t allow scripts, the calculator still works without it.