Generator size calculator
Enter how many of each thing you want to keep running during an outage. The calculator adds up the load and allows for the surge when a motor starts.
Look for a generator of
3,500 running watts
- Starting watts at least
- 4,400 watts
- Your running load
- 2,850 watts
- Biggest startup surge
- Furnace blower (+1,550 W)
Shop for this project
As an Amazon Associate, Measure the Dream earns from qualifying purchases.
Quick answers and tables: What size generator do I need?
How it works
Generators have two ratings. Running watts is what they can supply all day. Starting watts is the brief extra boost they can give when a motor kicks on, since fridges, pumps and furnace fans draw two to three times their running power for a second or two at startup.
The calculator adds the running watts of everything you chose, using typical figures for each appliance. It adds 20% headroom so the generator isn’t running flat out, and rounds up to the next 500 watts. For starting watts, it adds the extra surge of the single biggest motor, since they rarely all start at the same moment.
Example
With refrigerators or freezers 1, furnace blowers 1, sump pumps 1, well pumps 0, window air conditioners 0, microwaves 0, space heaters (1,500 W) 0, electric water heaters 0, lED light bulbs 10, tV, internet and phone chargers: yes, the answer is 3,500 running watts.
How to measure
List what you’d actually run during an outage, and check each appliance’s label or manual for its running watts. Motors, such as fridges, furnace blowers, sump pumps and well pumps, also need a burst of extra power to start, so the calculator adds the biggest starting surge to your total.
You don’t need everything running at once. Many people stagger loads, letting the fridge catch up, then running the well pump, so a smaller generator can cover more.
Generator size for common outage plans
Using typical appliance wattages. Your appliances may differ, so check their labels.
| What you’ll run | Running watts | Look for (running) | Starting watts |
|---|---|---|---|
| Fridge, a few lights, TV | 950 | 1,500 | 2,450 |
| + gas furnace blower | 1,800 | 2,500 | 3,350 |
| + sump pump | 2,850 | 3,500 | 4,400 |
| + well pump | 3,850 | 5,000 | 5,400 |
| Fridge, window AC, lights | 2,200 | 3,000 | 4,600 |
Common mistakes
- Running a generator indoors, in a garage or near a window. Generators make carbon monoxide that can kill in minutes. Run it outside, far from doors and windows, and use a CO alarm.
- Plugging a generator into a wall outlet. Backfeeding can electrocute utility workers. Use a transfer switch or interlock installed by an electrician.
- Ignoring starting watts. A generator that covers your running load can still stall when a pump or compressor kicks on.
- Using thin extension cords. Long or light cords overheat and drop voltage. Use a heavy-gauge outdoor cord sized for the load.
Tips before you buy
- Check the labels. Your own appliances may draw more or less than these typical figures, and the label or manual gives the real number.
- Never run a generator indoors, in a garage or near windows. Carbon monoxide from the exhaust can kill within minutes. Keep it at least 20 feet from the house and use a battery CO alarm inside.
- Connecting a generator to your home’s wiring needs a transfer switch or interlock installed by an electrician. Backfeeding through an outlet can kill utility workers.
- Store fuel safely and run the generator for a few minutes every month or two so it starts when you need it.
Common questions
What size generator do I need for a refrigerator, furnace and sump pump?
About 3,500 running watts and 4,400 starting watts, including a few LED lights and a TV, using typical appliance figures.
What size generator will run a whole house?
Running central air, an electric range and an electric water heater usually takes a home standby generator of 20,000 watts or more. A 5,000 to 7,500 watt portable covers the essentials: fridge, furnace fan, sump pump, lights and outlets.
What’s the difference between running and starting watts?
Running watts is what the generator supplies continuously. Starting watts is a brief extra burst for motors that draw more power for a second or two as they start.